When idle, the KEGMETER automatically sequences thru several of these displays and your user messages to give you and your guests something to watch. All listed displays can be selected using the MENU switch.
Shows day of week, date, and time of day (12 hour AM/PM ).
Shows how much beer is gone. Selectable units include pounds (LB), %, GAL, Empty/Full bar graph, db down, l, raw counts (cy), or ounces (oz).
Shows how much beer is left, which is difference between selected keg size and amount of beer gone.
Shows how much beer was most recently served.
Shows how much beer has been served since last pressed the ACK button while in Change mode.
Shows an estimate of how long the keg will last. Estimate is made by dividing the beer remaining by the average rate of consumption since the first serving. The most interesting thing about this display is that if it is steadily decreasing you know you will finish the keg.
Shows time elapsed since the first serving.
Internal temperature of the Electronic Control Unit
Temperature read by the keg temperature sensor.
Pressure of incoming CO2 gas.
Outlet pressure of solenoid operated valve #1. SOV 1 opens the faucet.
Outlet pressure of solenoid operated valve #2. SOV 2 closes the faucet.
Charge power input voltage.
Battery voltage.
Internal supply voltage monitor.
Peak flowrate measured during last serving.
Actual flowrate.
Average flowrate since first serving.
When an alarm is activated, it flashes the master caution lights, activates the alarm tone (if not muted), and flashes the applicable message below on the display:
Activated by selecting TEST on the alarm mode toggle switch.
Activated if ECU internal temperature exceeds limit.
Activated upon loss of ECU temperature sensor readings.
Activated when the beer flowmeter senses excessively high flowrates. This condition is almost exclusively caused by a lack of beer in the line.
Activated if beer temperature gets too hot.
Activated if beer temperature gets below freezing.
Activated upon loss of beer temperature sensor readings.
Activated if CO2 pressure gets too high or low, respectively.
Activated when you're almost out of beer.
Activated if the battery voltage gets low.
Activated when the power input voltage gets low.
Activated after performing a keg RESET when starting a new keg.
Activated if the faucet is manually closed during an automatic serving.